Integral Ferrule Nut/Tube Construction

Laboratory testing of PFA fittings and FEP/PFA tubing (grooved with an Entegris grooving tool) showed successful results under extreme conditions of heat and pressure. Performance reliability is dependent on the care and caution used in grooving the tube and tightening the fitting properly.

Note: The tubing used must be heavy walled (.047" to .062" wall thickness) and must meet Galtek® tubing specifications. 1/8" uses .030" wall thickness.

 

Click to enlarge
Click to enlarge

C 4-4 N

    "N" denotes that a ferrule nut or nuts have been assembled on the fitting body.
  The size and type of fitting connections is denoted. If it is a tube to pipe connector, the number preceding the dash denotes the tube connection size and the number following the dash denotes the pipe thread size. (i.e., 4 = 4/16" or 1/4", 6m = 6 mm)
Letter or combination of letters denotes the fitting style.
(i.e., C  =  Male Connector, tube to pipe)

FN = Ferrule Nut
FC = Female Connector - Tube to Pipe
PM = Panel Mount - Straight Union
FP = Ferrule Plug
E = Male Elbow - Tube to Pipe
UE = Union Elbow
HN = Half Nut
FE = Female Elbow - Tube to Pipe
UT = Union Tee
CP = Cap Plug
PMC = Panel Mount Connector - Tube to Pipe
BT = Male Branch Tee - Tube to Pipe
C = Male Connector - Tube to Pipe
SU = Straight Union
RT = Male Run Tee - Tube to Pipe